Chapter 4: The Legal Requirements of Boating
Fire Extinguishers
Extinguishers are classified by a letter and number symbol. The
number indicates the relative size of the extinguisher, and the
letter indicates the type of fire it will extinguish.
- Type A fires are of combustible solids like
wood.
- Type B fires are of flammable liquids like
gasoline or oil.
- Type C fires are electrical fires.
All vessels are required to have a Type B fire extinguisher(s)
on board if one or more of the following conditions exist:
- Inboard engine
- Closed compartments where portable fuel tanks may be stored
- Double-bottoms not sealed to the hull or which are not completely
filled with flotation material
- Closed living spaces
- Closed storage compartments in which flammable or combustible
materials may be stored
- Permanently installed fuel tanks
Approved types of fire extinguishers are identified by the following
marking on the label—“Marine Type USCG Approved”—followed
by the type and size symbols and the approval number.
Use this chart to determine the type and quantity of fire extinguishers required for your vessel.
| Length of Vessel |
Without Fixed System |
With Fixed System * |
| Less than 26 feet |
one B-I |
None |
| 26 feet to less than 40 feet |
two B-I or one B-II |
one B-I |
| 40 feet to less than 65 feet |
three B-I or one B-II and one B-I |
two B-I or one B-II |
| * refers to a permanently installed fire extinguisher system |
Extinguishers should be placed in an accessible area—not near the engine or in a compartment, but where they can be reached immediately. Be sure you know how to operate them.
Fire extinguishers must be maintained in usable condition.
- Extinguishers should be serviced at least every two years. See the label for additional servicing information.
- Inspect extinguishers regularly to ensure the following.
- Seals and tamper indicators are not broken or missing.
- Pressure gauges or indicators read in the operable range.
- There is no physical damage, corrosion, leakage, or clogged nozzles.
Fire Extinguisher Charge Indicators
Check the charge level of your fire extinguishers regularly. Replace them immediately if they are not fully charged.
To check this style of extinguisher, depress the green button. If it is fully charged, the green button should pop back out immediately. |
 |
On this style of fire extinguisher, the needle indicator should be in the "full" range. |
 |
Backfire Flame Arrestors
Because boat engines may backfire,
all powerboats (except outboards) that are fueled with gasoline
must have an approved backfire flame arrestor on each carburetor.
Backfire flame arrestors are designed to prevent the ignition of
gasoline vapors in case the engine backfires.
Backfire flame arrestors must be:
- In good and serviceable condition
- U.S. Coast Guard–approved (must comply with SAE J-1928
or UL 1111 standards)
Periodically clean the flame arrestor(s) and check for any damage.
Ventilation Systems
Ventilation systems are crucial. Their purpose is to avoid explosions by removing
flammable gases. Properly installed ventilation systems greatly reduce the chance of
a life-threatening explosion.
- All gasoline-powered vessels, constructed in a way that would entrap fumes,
must have at least two ventilation ducts fitted with cowls to remove the fumes.
At least one exhaust duct must extend from the open atmosphere to the lower
bilge. At least one intake duct must extend from a point at least midway to the
bilge or below the level of the carburetor air intake.
- If your vessel is equipped with a power ventilation system, turn it on for at
least four minutes in either of these situations:
- After fueling
- Before starting the engine
- If your vessel is not equipped with a power ventilation system (for example,
a personal watercraft), open the engine compartment and sniff for gasoline
fumes before starting the engine.
 |
Vessels built after July 31, 1980, which contain power exhaust blowers in gasoline engine compartments, must have the above warning sticker placed near the instrument panel. |
Powerboats are built to ventilate the engine when underway. As the boat moves along, an air intake scoops up fresh air and forces it down the air duct into the engine compartment. The exhaust sucks out the explosive fumes from the lowest part of the engine and fuel compartments. |
 |
Mufflers and Noise Level Limits
Vessel operators may not hear sound signals or voices if the engine is not
adequately muffled.
- All vessels manufactured after January 1, 1990, operating on Maryland
waters must be equipped with a muffler system in good working order and in
constant operation to suppress engine noise.
- You may not remove or modify a muffler or muffling system if the result is an
increase in noise level.
- No person may operate a vessel on Maryland waters that emits noise in excess
of 90 db(A).
- Vessels involved in a marine event approved by the U.S. Coast Guard or the
Maryland Department of Natural Resources are exempt from the requirements
above.
Vessel Safety Checks
The U.S. Coast Guard Auxiliary and U.S. Power Squadrons will perform a Vessel Safety Check (VSC) of your vessel and equipment free of charge. This inspection covers federal and state requirements. If your vessel meets all VSC requirements, you will receive a VSC decal. If your vessel fails to meet all requirements, no report is made to any law enforcement agency.
|