Chapter 4: The Legal Requirements of Boating
Fire Extinguishers

Extinguishers are classified by a letter and number symbol. The number indicates the relative size of the extinguisher, and the letter indicates the type of fire it will extinguish.

  • Type A fires are of combustible solids like wood.
  • Type B fires are of flammable liquids like gasoline or oil.
  • Type C fires are electrical fires.

All power-driven vessels over 26 feet in length are required to carry Type B fire extinguishers. All power-driven vessels 26 feet in length or less, including PWCs, are required to have a Type B fire extinguisher on board if one or more of the following conditions exist:

  • Closed compartments
  • Permanently installed fuel tanks
  • Double-bottoms that are not sealed to the hull or that are not completely filled with flotation material
  • Closed living spaces

Approved types of fire extinguishers are identified by the following marking on the label—“Marine Type USCG Approved”—followed by the type and size symbols and the approval number.

Use this chart to determine the type and quantity of fire extinguishers required for your vessel.

Length of Vessel Without Fixed System With Fixed System *
Less than 26 feet one B-I None
26 feet to less than 40 feet two B-I or one B-II one B-I
40 feet to less than 65 feet three B-I or one B-II and one B-I two B-I or one B-II
* refers to a permanently installed fire extinguisher system

Extinguishers should be placed in an accessible area—not near the engine or in a compartment, but where they can be reached immediately. Be sure you know how to operate them.

Fire extinguishers must be maintained in usable condition. Inspect extinguishers regularly to ensure the following.

  • Seals and tamper indicators are not broken or missing.
  • Pressure gauges or indicators read in the operable range.
  • There is no physical damage, corrosion, leakage, or clogged nozzles.

Fire Extinguisher Charge Indicators

Check the charge level of your fire extinguishers regularly. Replace them immediately if they are not fully charged.

To check this style of extinguisher, depress the green button. If it is fully charged, the green button should pop back out immediately.

Fire extinguisher charge indicator: Button style

On this style of fire extinguisher, the needle indicator should be in the "full" range.

Fire extinguisher charge indicator: Needle style

Backfire Flame Arrestors

Because boat engines may backfire, all powerboats (except outboards) that are fueled with gasoline must have an approved backfire flame arrestor on each carburetor. Backfire flame arrestors are designed to prevent the ignition of gasoline vapors in case the engine backfires.

Backfire flame arrestors must be:

  • In good and serviceable condition
  • U.S. Coast Guard–approved (must comply with SAE J-1928 or UL 1111 standards)

Periodically clean the flame arrestor(s) and check for any damage.

Ventilation Systems

Ventilation systems are crucial. Their purpose is to avoid explosions by removing flammable gases. Properly installed ventilation systems greatly reduce the chance of a life-threatening explosion.

  • All gasoline-powered vessels, constructed in a way that would entrap fumes, must have at least two ventilation ducts fitted with cowls to remove the fumes. At least one exhaust duct must extend from the open atmosphere to the lower bilge. At least one intake duct must extend from a point at least midway to the bilge or below the level of the carburetor air intake.
  • If your vessel is equipped with a power ventilation system, turn it on for at least four minutes in either of these situations:
    • After fueling
    • Before starting the engine
  • If your vessel is not equipped with a power ventilation system (for example, a personal watercraft), open the engine compartment and sniff for gasoline fumes before starting the engine.

Boat on fire

Vessels built after July 31, 1980, which contain power exhaust blowers in gasoline engine compartments, must have the above warning sticker placed near the instrument panel.

Boat ventilation

Mufflers

Vessel operators may not hear sound signals or voices if the engine is not adequately muffled. All vessel engines should be equipped with an effective muffling device.

Vessel safety check decalVessel Safety Checks

The U.S. Coast Guard Auxiliary and U.S. Power Squadrons will perform a Vessel Safety Check (VSC) of your vessel and equipment free of charge. This inspection covers federal and state requirements. If your vessel meets all VSC requirements, you will receive a VSC decal. If your vessel fails to meet all requirements, no report is made to any law enforcement agency.

 

Vessel safety check
Separator
North Dakota
Game and Fish Department

Boat Ed, provider of official boating safety courses for more than 40 states
Find Another
Boating Safety Course

Course Material
Boating Terms
Get Certified
< Back to Previous Page Table of Contents Go to Next Page >
 
Online boating license and certification course last modified: April 8, 2009
Email concerning this boat safety course.
NASBLA logo Questions? Call Boat Ed at 1-800-830-2268
Copyright © 1998-2009 Boat Ed. All rights reserved.
Review Boat Ed's privacy policy.
Approved by NASBLA and recognized by the U.S. Coast Guard
U.S. Coast Guard logo
Rounder